Related Experiment Video
Updated: Aug 15, 2026

A Standardized Approach to Extra-Oral and Intra-Oral Digital Photography
Published on: July 22, 2022
Variation between experienced observers in the interpretation of accident and emergency radiographs
P J Robinson1, D Wilson, A Coral
1Clinical Radiology Department, St James's University Hospital, Leeds, UK.
Abstract:
Skill mix and role extension initiatives have highlighted the difficulty of establishing quality standards for the accuracy of plain film reporting. An acceptable performance might be one which is indistinguishable from that of a group of experienced consultant radiologists. In order to assess the feasibility of setting such a standard, the variation between experienced observers must first be established. This study examines the variation found between three observers with the three major types of plain film examination. 402 plain film examinations (205 skeletal, 100 chest and 97 abdominal) performed on accident and emergency patients were reported retrospectively and independently by three experienced radiologists. The clinical data supplied on the request cards were available to the readers. Each examination was categorized by each reader as being normal, as showing significant abnormality relevant to the current clinical problem, or as showing insignificant or irrelevant abnormality. Concordance between all three readers was found in 51%, 61% and 74% of abdominal, chest and skeletal radiographs, respectively. Weighted kappa values confirmed that the level of agreement between pairs of observers was higher with skeletal radiographs (kappa w = 0.76-0.77) than with chest (kappa w = 0.63-0.68), or abdominal (kappa w = 0.50-0.78) examinations. However, the frequency of major disagreements (at least one reader reporting "normal" and one reporting "relevant abnormality") was similar for abdominal (11%), chest (12%) and skeletal (10%) radiographs. When the reports were reclassified into only two groups--either significantly abnormal or not--pairs of observers disagreed on 9-10% of skeletal, 11-19% of chest and 8-18% of abdominal cases. The average incidence of errors per observer was estimated to be in the range 3-6%. The magnitude of interobserver variation in plain film reporting is considerable, and must be taken into account when designing assessment techniques and setting quality standards for this activity.
Related Concept Videos
X-ray Imaging
Radiological Investigation I: X-ray and CT
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...

