The measurement of venous haematocrit in patients with polycythaemia vera
Related Experiment Video
Updated: Oct 19, 2026

Measurement of the Hepatic Venous Pressure Gradient and Transjugular Liver Biopsy
Published on: June 18, 2020
B Andréasson1, E Wahlström, S Jacobsson
1Medical Clinic, Kärnsjukhuset, Skövde, Sweden.
Objective:
In clinical practice, patients with polycythaemia vera (PV) are monitored by measurement of venous packed cell volume (PCV). However, whereas treatment recommendations are still based upon studies in which the results were obtained with the centrifuged microhaematocrit, currently in most instances automated blood cell counters are used to calculate PCV. In a group of patients with polycythaemia we therefore compared the results obtained by the microhaematocrit method with PCV calculated by haematology analysers.
Design:
The study was carried out on a prospective basis. Duplicate venous blood samples were collected. The centrifuged microhaemotocrit was obtained by using an IEC Micro-MB Centrifuge. Depending on different routine methods used in the participating hospitals, the blood cell counter PCV was calculated using Coulter STKS, Bayer Technicon H2 or H3.
Setting:
Patients were included from four Swedish university hospitals: Akademiska (Uppsala), Huddinge and Karolinska (Stockholm) and Sahlgrenska (Göteborg).
Subjects:
Seventy-four patients with PV and 10 patients with secondary polycythaemia were included and a total of 150 duplicate blood samples were analysed from these subjects.
Results:
In the 150 measurements the mean blood cell counter calculated PCV was 0.448 +/- 0.037; the mean for centrifuged microhaematocrit was 0.467 +/- 0. 037 and the difference between means was highly significant (P = 6.8 x 10-25). The means for centrifuged haematocrit and calculated PCV differed significantly in the groups of PV patients treated with phlebotomy only, hydroxyurea or radiophosphorous (P < 0.0001, respectively). In PV patients treated with alpha-interferon and in patients with secondary polycythaemia the difference in means did not reach statistical significance (P = 0.07 and P = 0.13, respectively). The groups of patients with MCV <80 fL and >/=80 fL both presented significant differences between means for calculated PCV and centrifuged haematocrit.
Conclusions:
If PV patients are monitored with blood cell counter calculated PCV it appears that the therapeutic goal should be to maintain the calculated PCV below 0.43, provided the local differences in calculated PCV and centrifuged haematocrit are of the same magnitude as in this study.
Related Concept Videos
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Venous Thrombosis IV: Nursing Management
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Venous Return
What is Venous Return?
Venous return refers to the rate at which blood flows back to the heart from the body's peripheral veins. It's an integral part of the circulatory system as it...
Veins as Blood Reservoirs
Venous Thrombosis I: Introduction