Development of diagnostic thresholds for automated measurement of blood pressures in adults
1Hypertension and Cardiovascular Rehabilitation Unit, Department of Molecular and Cardiovascular Research, University of Leuven, Leuven, Belgium. jan.staessen@med.kuleuven.ac.be
Abstract:
In clinical medicine, blood pressure is usually measured by conventional sphygmomanometry. Although it seems simple at first sight, this procedure is fraught with potential sources of error, which may arise from the subject, the observer, the sphygmomanometer or the overall application of the technique. Automated techniques of blood pressure measurement, such as ambulatory monitoring and self-measurement, reduce the limitations of conventional sphygmomanometry. However, the diagnostic thresholds applicable for conventional sphygmomanometry cannot be extrapolated to automated measurements. During the past 10 years criteria for normality have gradually been developed for ambulatory blood pressure (ABP) monitoring of adults. First, the distribution of the ABP in normotensive subjects and untreated hypertensive patients who had initially been recruited and classified on the basis of their conventional blood pressure was studied. Second, authors of various epidemiological studies investigated the distributions of the conventional blood pressure and the ABP in the population at large. Third, authors of several reports attempted to validate the preliminary thresholds for ambulatory monitoring by correlating the ABP to left ventricular hypertrophy, other intermediary signs of target-organ damage or the incidence of cardiovascular morbidity or mortality. Finally, clinical trials should be mounted to prove that it is beneficial to patients as well as cost-effective to diagnose and treat hypertension on the basis of ambulatory monitoring rather than solely under the guidance of conventional sphygmomanometry. For measurements of systolic/diastolic ABP in adults, the proposed upper limits of normotension are 130/80 mmHg for the 24h blood pressure and 135/85 and 120/70 mmHg for the daytime and night-time blood pressures, respectively; for the self-measured blood pressure 135/85 mmHg might be the upper limit of normality. With regard to ABP monitoring, a large database already supports the proposed diagnostic thresholds in terms of their associations with left ventricular hypertrophy and with the incidence of cardiovascular complications; the evidence to validate the thresholds for the self-recorded blood pressure, to a large extent, must still be collected. In conclusion, the newer techniques of blood pressure measurement are now well established in the diagnosis and management of adult subjects with hypertension.
More Related Videos
06:51Development of an Algorithm to Perform a Comprehensive Study of Autonomic Dysreflexia in Animals with High Spinal Cord Injury Using a Telemetry Device
Published on: July 29, 2016
05:51Measuring the Carotid to Femoral Pulse Wave Velocity (Cf-PWV) to Evaluate Arterial Stiffness
Published on: May 3, 2018
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(two-step method)
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Pre-Procedural Guidelines for Assessing Blood Pressure
Measurement of Blood Pressure