Speech audibility for listeners with high-frequency hearing loss.

C W Turner1, K J Cummings

  • 1Syracuse University, NY, USA. Christopher-Turner@uiowa.edu

American Journal of Audiology
|September 28, 1999
PubMed
Summary

For individuals with high-frequency hearing loss, amplifying sounds above 3000 Hz may not improve speech recognition. Benefits are limited when hearing loss exceeds 55 dB HL in these high frequencies.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Correction to: An exposé of Frappellian Motion.

Journal of comparative physiology. B, Biochemical, systemic, and environmental physiology·2023
Same author

An exposé of Frappellian Motion.

Journal of comparative physiology. B, Biochemical, systemic, and environmental physiology·2021
Same author

Opportunistic Invasive Cutaneous Fungal Infections Associated with Administration of Cyclosporine to Dogs with Immune-mediated Disease.

Journal of veterinary internal medicine·2017
Same author

Fecal shedding of Campylobacter jejuni and Campylobacter coli among feral pigs in Texas.

Zoonoses and public health·2017
Same author

Prevalence of Salmonella among waterfowl along the Texas Gulf coast.

Zoonoses and public health·2017
Same author

Faecal Campylobacter shedding among dogs in animal shelters across Texas.

Zoonoses and public health·2017

Area of Science:

  • Audiology
  • Speech-Language Pathology
  • Hearing Science

Background:

  • High-frequency hearing loss is common and can impact speech understanding.
  • The benefit of audibility in high-frequency regions for speech recognition is not fully understood.
  • Previous research suggests limitations in audibility benefits for certain hearing impairments.

Purpose of the Study:

  • To investigate the limitations on the benefit of audible speech information for listeners with high-frequency hearing loss.
  • To determine if speech recognition improves with increased audibility in high-frequency regions.
  • To compare audibility benefits across different hearing loss configurations.

Main Methods:

  • Speech recognition was tested in 10 listeners with varying degrees of high-frequency hearing loss.
  • Recognition performance was measured across a range of presentation levels.
  • Speech spectrum audibility was compared with pure-tone thresholds.

Main Results:

  • Speech recognition performance reached an asymptote below 100% for all listeners with hearing loss.
  • Audible speech in high-frequency regions (>= 3000 Hz) with hearing loss > 55 dB HL showed little to no improvement.
  • Increased speech audibility in lower frequencies improved recognition for a listener with severe-to-profound flat hearing loss.

Conclusions:

  • Providing amplification for severe high-frequency hearing loss (>= 3000 Hz) may not benefit many individuals.
  • Speech audibility benefits are frequency-dependent and influenced by the degree and configuration of hearing loss.
  • Understanding the limits of audibility is crucial for effective hearing aid fitting and speech rehabilitation strategies.