Related Experiment Video
Updated: Oct 19, 2026

Measuring the Carotid to Femoral Pulse Wave Velocity (Cf-PWV) to Evaluate Arterial Stiffness
Published on: May 3, 2018
Evaluation of arterial compliance in patients with carotid arterial atherosclerosis
1Department of Internal Medicine, Taichung Veterans General Hospital, Taiwan, ROC.
Insights
Patients with coronary artery disease (CAD) and carotid artery lesions show reduced carotid artery compliance. Atherosclerotic changes, including increased wall thickness, are linked to this decreased arterial compliance.
Area of Science:
- Vascular biology
- Cardiovascular imaging
- Biomechanical properties of arteries
Background:
- High-resolution peripheral vascular sonography assesses vessel compliance.
- Factors like age, hypertension, and atherosclerosis influence arterial compliance.
- Carotid artery compliance in patients with both coronary artery disease (CAD) and carotid artery lesions is understudied.
Purpose of the Study:
- To investigate if carotid artery compliance is reduced in patients with CAD and carotid artery lesions.
- To determine the relationship between decreased arterial compliance and vascular wall structure abnormalities.
Main Methods:
- Study included 12 patients with CAD and carotid artery disease, 13 with CAD only, and 13 controls.
- High-resolution peripheral vascular ultrasonography visualized the common carotid artery, measuring diameter and wall thickness.
- Carotid artery elastic properties were assessed using diameter and pressure measurements.
Main Results:
- Carotid artery walls were significantly thicker in patients with CAD (Groups II and III) compared to controls.
- Carotid distensibility was lower and Young's modulus of elasticity was higher in CAD patients, indicating reduced compliance.
- These changes in arterial compliance and wall thickness were significantly different between CAD subgroups.
Conclusions:
- Mechanical properties of carotid arteries offer reliable insights into atherosclerotic changes.
- Increased carotid artery wall thickness is associated with decreased arterial compliance in atherosclerosis.
Background:
High-resolution peripheral vascular sonography has the capability to determine vessel compliance. A number of factors affect compliance in humans, including age, hypertension and atherosclerosis. However, compliance in patients with coronary artery disease (CAD) combined with carotid artery lesions has not been well studied. The objectives of this study were: 1) to determine whether carotid artery compliance is reduced in patients with CAD and carotid artery lesions, and 2) to determine whether decreased arterial compliance is related to an abnormality in vascular wall structure.
Methods:
The study participants included 12 patients with CAD and carotid artery disease (group III), 13 patients with CAD only (group II) and 13 age-matched normal subjects who served as controls (group I). High-resolution peripheral vascular ultrasonography was performed to directly visualize the common carotid artery and to measure its diameter and wall thickness. Carotid artery elastic properties were determined relative to arterial diameter and pressure generated within the heart.
Results:
Carotid artery walls were thicker in Group II and III patients than in normal subjects (1.49 +/- 0.03 mm, 1.98 +/- 0.04 mm, vs 1.22 +/- 0.03 mm, p < 0.05 and p < 0.01). There were significant differences in wall thickness between subgroups of CAD patients (p < 0.01). Carotid distensibility was lower (21.8 +/- 1.2 x 10(-6).N-1.m2, 14.8 +/- 1.7 x 10(-6).N-1.m2, vs 25.6 +/- 1.5 x 10(-6).N-1.m2; p < 0.05 and p < 0.01) and Young's modulus of elasticity was higher (3.12 +/- 0.43 x 10(5).Nm-2, 4.18 +/- 0.30 x 10(5).Nm-2, vs 2.34 +/- 0.23 x 10(5).Nm-2; p < 0.05 and p < 0.01) in group II and III patients than in normal subjects. These two indices of carotid artery compliance also differed between subgroups of CAD (p < 0.01). Increased wall thickness may occur secondary to changes in the architectural structure of the vessel wall, and these atherosclerotic changes lead to decreased compliance of arteries.
Conclusion:
The mechanical properties of the carotid arteries provide reliable information regarding changes caused by atherosclerosis.
Related Concept Videos
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Atherosclerosis II: Clinical Manifestations and Diagnostic Tests
Assessment of blood pressure in brachial artery(two-step method)
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of the Cardiovascular System II: Inspection
Head and Neck
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...