Related Experiment Videos
High-performance liquid chromatographic assay of hydroperoxide levels in oxidatively modified lipoproteins
Y Yamaguchi1, S Kagota, M Kunitomo
1Faculty of Pharmaceutical Sciences, Mukogawa Women's University, Hyogo, Japan. yusan@mwu.mukogawa-u.ac.jp
Abstract:
An anion-exchange HPLC method has been developed for the chemiluminescence (CL) assay of hydroperoxide (HPO) levels in native and oxidized low density lipoproteins (N- and Ox-LDLs, respectively) of Watanabe heritable hyperlipidemic (WHHL) rabbits. The method involves anion-exchange HPLC separation in N- and Ox-LDLs using a DEAE-glucomannan gel, and direct CL detection of HPOs in them without extraction of the lipids following postcolumn reaction with isoluminol, microperoxidase and Triton X-100. Addition of Triton X-100, which could solubilize lipids, were essential for the detection of HPOs in N- and Ox-LDLs. With an increase in the degree of oxidation, Ox-LDL was more retained on the DEAE-glucomannan gel with a concomitant increase in the CL intensity. The proposed method could analyze the HPO levels in N- and Ox-LDLs of WHHL rabbits without extraction of the lipids.