Related Experiment Video
Updated: Oct 18, 2026

An Anaerobic Biosensor Assay for the Detection of Mercury and Cadmium
Published on: December 17, 2018
[In vitro evaluation of mercury leakage from dental amalgam using atomic absorption spectrophotometry]
P F Lugliè1, G Filia, G Chessa
1Istituto di Clinica Odontoiatrica, Università degli Studi, Sassari.
Objective:
The use of silver amalgam as a tooth filler is under constant critical review because of its mercury content. After a review of the literature on this subject, in vitro spectrophotometry was used to assay the release of mercury by these amalgams in basal conditions.
Methods:
The experiment was conducted in two phases using standard doses of amalgam. In Phase 1 Black Class I cavities were created in extracted teeth that were big enough to take the required dose of amalgam. In some cases the material was inserted in a single operation, while in others the amalgam was introduced in three stages. Some of the cavities were cleansed with cotton buds bathed in ethyl alcohol, while others were not. All the drilled teeth were imbued in a bath of artificial saliva held at a constant temperature. In the second experiment, crushed amalgam was immersed in a similar bath of artificial saliva but otherwise untreated. The saliva was assayed after different time lapses using atomic absorption spectrophotometry and the FIAS technique.
Results:
The results showed extremely variable but always modest quantities of free mercury in the artificial saliva.
Conclusions:
The findings suggest that not all the mercury available in the amalgamation phase is involved in the formation of the crystalline reticulum and that the percentage of mercury bonded is different every time. While the titre of free mercury encountered was always extremely low and hard to predict, it cannot be ignored.
Related Concept Videos
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...
Atomic Absorption Spectroscopy: Overview
When irradiated by EMR of a particular wavelength, these...
Atomic Fluorescence Spectroscopy
Atomic Absorption Spectroscopy: Atomization Methods
Atomic Absorption Spectroscopy: Instrumentation
The atomizer used in AAS can be either a flame atomizer or an...
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...