Related Experiment Video
Updated: Oct 18, 2026

Laparoscopic Repair of Para-Esophageal Hernia Using Absorbable Biosynthetic Mesh
Published on: September 11, 2021
Pneumomediastinum as a complication of extraperitoneal laparoscopic inguinal hernia repair
1Servicio de Cirugía General y Aparato Digestivo, Complejo Hospitalario de Ciudad Real, Spain.
Abstract:
A 52-year-old man with left indirect groin hernia was admitted for elective inguinal repair using the totally extraperitoneal (TEP) approach. After an uneventful intubation, TEP repair of the hernia was performed with three midline trocars. Immediately after extubation, the patient noted severe chest pain. There was a decrease in PaO2 saturation, and neck subcutaneous emphysema was detected. There was no emphysema of the abdomen or of the back. A chest film and thoracic computed tomographic (CT) scan confirmed the presence of pneumomediastinum without pneumothorax. The patient was discharged without complications.
Related Concept Videos
Pneumothorax-II
Clinical Manifestations:
Esophageal Perforation-I: Introduction
The location of esophageal perforation can vary, occurring anywhere along the esophagus.
Esophageal Perforation-II: Clinical Manifestations and Management
Clinical Manifestations:
Pneumothorax II: Pathophysiology