Related Experiment Video
Updated: Jul 20, 2026

Evaluation of Respiratory System Mechanics in Mice using the Forced Oscillation Technique
Published on: May 15, 2013
Effects of inhalation exposures to an M1-receptor agonist on ventilation in rhesus monkeys
D L Allen1, P A Leiter, R L Tielking
1Toxicology Research Laboratories, Lilly Research Laboratories, Eli Lilly and Company, Greenfield, IN 46140, USA.
Abstract:
Information was needed on effects of possible occupational inhalation exposure to an M1-receptor agonist (xanomeline) such as might occur during the manufacturing process. Both acute and repeated inhalation exposures to xanomeline were carried out in six male rhesus monkeys using a head-dome exposure system. Exposure concentrations ranged from 0.3 to 10 mg/m3. The exposure durations were up to 2 weeks. Decreases in tidal volume and increases in respiratory frequency were both time and concentration related during acute exposures. These effects were blocked with atropine pre-treatment. Correlation with pulmonary resistance measurements in two monkeys suggested that these were bronchoconstrictive changes that increased with severity with time at a given concentration and with concentration when measured after a constant exposure time. The dose-response was relatively steep with 10 mg/m3 becoming intolerable to the monkeys after approximately 15 minutes, but no measurable effects were observed at 0.3 mg/m3 after up to 4 hours of exposure. To investigate the effects of repeated exposures, monkeys were exposed for 4 hr/day, 5 days/wk for 2 weeks to 0.0 (air only), 0.3, and 1.2 mg xanomeline/m3 of air. When compared to the air-only exposure, 0.3 mg/m3 caused no significant changes in tidal volume. In contrast, 1.2 mg/m3 caused a rapid and significant decrease in tidal volume that was sustained throughout the 4-hr exposure. A slower rise in breathing frequency also occurred. Repeated exposures did not alter the effects seen after a single exposure. It is concluded that xanomeline, a M1-receptor agonist, can acutely alter normal ventilation in non-human primates at airborne concentrations > or = 0.6 mg/m3 and should be carefully controlled in a manufacturing environment. The no-observed-effect concentration was 0.3 mg/m3.
Related Concept Videos
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...

