Dry platelets with the Dideco Excel apparatus.

M Valbonesi1, R Bruni, G Florio

  • 1Immunohematology Services, San Martino University Hospital, Genova, Italy.

Transfusion Science
|October 28, 1999
PubMed
Summary
This summary is machine-generated.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Anaphylaxis Quality of Life Scale for adults: the validation on the Italian allergic patients.

European annals of allergy and clinical immunology·2025
Same author

Patients with cancer who will be cured and projections of complete prevalence in Italy from 2018 to 2030.

ESMO open·2024
Same author

Detection and full genomic sequencing of rare hepatitis E virus genotype 4d in Italian wastewater, undetected by clinical surveillance.

The Science of the total environment·2023
Same author

Epidemiological and molecular characterization of HBV and HCV infections in HIV-1-infected inmate population in Italy: a 2017-2019 multicenter cross-sectional study.

Scientific reports·2023
Same author

Optimization methods for the imputation of missing values in Educational Institutions Data.

MethodsX·2021
Same author

Can Longo stapled haemorrhoidopexy for haemorroids be a day-case procedure?

Il Giornale di chirurgia·2020

Dry platelet collection using the Dideco Excel apparatus eliminates the need for post-collection resuspension, ensuring high-quality platelets for transfusion. This method prevents transfusion reactions and reduces HLA immunization risks.

Area of Science:

  • Transfusion Medicine
  • Hematology
  • Biotechnology

Background:

  • Dry platelets are crucial for preventing transfusion reactions and HLA immunization.
  • Previous methods required post-collection resuspension in non-plasma solutions.
  • Newer cell separators offer integrated solutions for dry platelet collection.

Purpose of the Study:

  • To evaluate the efficacy and quality of dry platelet collection using the Dideco Excel apparatus with an integrated resuspension system.
  • To compare this novel method with conventional platelet collection techniques.

Main Methods:

  • Utilized the Dideco Excel apparatus for cyclic platelet collection with integrated resuspension.
  • Processed 53 collections, including 21 erythrothrombocytapheresis procedures.

Related Experiment Videos

  • Evaluated platelet yield, white blood cell (WBC) contamination, and platelet quality markers (aggregation, morphology, CD62 expression).
  • Main Results:

    • Achieved an average platelet yield of 4.67 x 10(11) within 60-65 minutes.
    • Maintained low WBC contamination, averaging 2.6 x 10(5).
    • Platelet quality was satisfactory, comparable to conventional methods.

    Conclusions:

    • The Dideco Excel system provides an efficient and effective method for collecting high-quality dry platelets.
    • This integrated system simplifies the collection process and maintains platelet integrity.
    • The findings support the use of this technology for improved transfusion safety.