Related Experiment Video
Updated: Oct 18, 2026

Gene Regulation and Targeted Therapy in Gastric Cancer Peritoneal Metastasis: Radiological Findings from Dual Energy CT and PET/CT
Published on: January 22, 2018
Positron emission tomography of esophageal carcinoma using (11)C-choline and (18)F-fluorodeoxyglucose: a novel method
O Kobori1, Y Kirihara, N Kosaka
1Department of Surgery, International Medical Center of Japan, Tokyo, Japan.
Background:
Accurate preoperative staging is an important but difficult problem in determining therapy for patients with esophageal carcinoma. Positron emission tomography (PET) is used with [methyl-(11)C]choline ((11)C-choline) and 2-[(18)F]fluoro-2-deoxy-D-glucose ((18)F-FDG) to detect a variety of malignancies. The authors used PET with both of these agents to detect lymph node metastases in patients with esophageal carcinoma.
Methods:
Lymph node metastases in 33 patients with biopsy-proven esophageal carcinoma (16 patients with tumors classified as T1 and 17 patients with tumors classified as T2-4) was examined by PET using (11)C-choline and (18)F-FDG, and the accuracy of the results was correlated with pathology findings after surgery.
Results:
(11)C-choline PET was more effective than (18)F-FDG PET and computed tomography (CT) in detecting very small metastases localized in the mediastinum. It was ineffective, however, in detecting metastases localized in the upper abdomen, because of the normal uptake of (11)C-choline in the liver. (18)F-FDG PET was superior to CT in detecting metastases in the mediastinum and the upper abdomen, whereas (11)C-choline PET was superior to (18)F-FDG PET in detecting metastases in the mediastinum. When (11)C-choline PET and (18)F-FDG PET were used in combination, they were very effective in evaluating the lymph node status in both the mediastinum and the upper abdomen, and detected 85% of the metastatic lymph nodes (n = 46).
Conclusions:
In this study, the combination of (11)C-choline PET and (18)F-FDG PET was very effective in evaluating the lymph node status of patients with esophageal carcinoma preoperatively.
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...