Clinical application of a blood pressure autoregulation system during hypotensive anesthesia
1Department of Surgery and Surgical Basic Science, Kyoto University, 54 Shogoin Kawara-cho, Sakyo-ku, Kyoto 606-8507, Japan.
Abstract:
A blood pressure autoregulation system based on the state-predictive control method was developed to minimize intraoperative blood loss and hence avoid blood transfusion. In this report, the system is further improved by incorporating fuzzy logic with a fail-safe function and an individual parameter-identifying function. The safety and stability of this system had been confirmed by preclinical experiments with dogs. Thereafter clinical application with 17 patients was conducted to maintain their mean arterial pressure at around 60 mmHg during major surgery. The use of this system resulted in decreased blood loss and more speedy and accurate surgery due to a clearer surgical field. Unwanted effects of hypotension were not observed clinically or in laboratory tests. This system is therefore safe, stable, and effective in reducing the blood loss during major surgery that otherwise might cause substantial blood loss.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(two-step method)
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Pre-Procedural Guidelines for Assessing Blood Pressure
Measurement of Blood Pressure
Autoregulation of Blood Flow
Chemical Signaling in Autoregulation
Chemical signaling operates at the precapillary sphincter level, inciting either contraction or relaxation.