Use of infrared thermography to detect inflammation caused by contaminated growth promotant ear implants in cattle
M F Spire1, J S Drouillard, J C Galland
1Food Animal Health and Management Center, College of Veterinary Medicine, Kansas State University, Manhattan 66506, USA.
Objective:
To compare the infrared thermographic appearance of bovine ears that had received contaminated growth promotant implants with ears that had received clean implants and ears without implants.
Design:
Prospective study.
Animals:
32 yearling crossbred beef steers with a mean weight of 322 kg (708 lbs).
Procedure:
Contaminated (n = 16) and clean (16) implants were placed in the ears of feedlot cattle. Nonimplanted (n = 32) ears served as a within-animal control for thermographic comparisons. Images of rostral and caudal surfaces were obtained during a 21-day period, using an infrared thermal imaging radiometer. Repeated measures ANOVA was used to determine the relationship between mean temperature in a zone on the rostral surface of the ear and at 3 locations (proximal, middle, distal) on the caudal surface of the ear (response variables) with treatment (ears with contaminated implants or clean implants vs control ears with no implants), time (repeated day of measurement), and interactions among these variables.
Results:
Significant temperature differences existed between ears with contaminated implants and control ears. Temperatures for ears with clean implants were significantly higher than control ears on day 2. At low ambient temperatures when the ears became wet, a greater temperature contrast was detected between ears with contaminated implants and control ears.
Conclusions And Clinical Relevance:
Thermal imaging of the ears of feedlot cattle is a noninvasive diagnostic tool that can be used to identify cattle with abscesses caused by contaminated growth-promotant implants.
Related Concept Videos
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...