Related Experiment Video
Updated: May 11, 2026

Three-Dimensional Cephalometric Landmark Annotation Demonstration on Human Cone Beam Computed Tomography Scans
Published on: September 8, 2023
A cone-beam reconstruction algorithm for circle-plus-arc data-acquisition geometry
Abstract:
In cone-beam computerized tomography (CT), projections acquired with the focal spot constrained on a planar orbit cannot provide a complete set of data to reconstruct the object function exactly. There are severe distortions in the reconstructed noncentral transverse planes when the cone angle is large. In this work, a new method is proposed which can obtain a complete set of data by acquiring cone-beam projections along a circle-plus-arc orbit. A reconstruction algorithm using this circle-plus-arc orbit is developed, based on the Radon transform and Grangeat's formula. This algorithm first transforms the cone-beam projection data of an object to the first derivative of the three-dimensional (3-D) Radon transform, using Grangeat's formula, and then reconstructs the object using the inverse Radon transform. In order to reduce interpolation errors, new rebinning equations have been derived accurately, which allows one-dimensional (1-D) interpolation to be used in the rebinning process instead of 3-D interpolation. A noise-free Defrise phantom and a Poisson noise-added Shepp-Logan phantom were simulated and reconstructed for algorithm validation. The results from the computer simulation indicate that the new cone-beam data-acquisition scheme can provide a complete set of projection data and the image reconstruction algorithm can achieve exact reconstruction. Potentially, the algorithm can be applied in practice for both a standard CT gantry-based volume tomographic imaging system and a C-arm-based cone-beam tomographic imaging system, with little mechanical modification required.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Accuracy, limits, and approximation
Accuracy is defined as the closeness of the measured value to the true or actual value. In engineering mechanics, repeated measurements are taken during theoretical or experimental analyses to ensure that the result is precise and accurate.
The accuracy of any solution is based on the...
Centroid of a Body: Problem Solving
The x-coordinates and y-coordinates of each element's...
Centroid for the Paraboloid of Revolution
The centroid for the paraboloid of revolution is the point where all the mass of the paraboloid is concentrated. This centroid is important for engineering applications, as it determines how forces are...
Circles
Arc Length of a Curve: Problem Solving

