Linear projection method for automatic slice shimming.

J Shen1, D L Rothman, H P Hetherington

  • 1The Nathan S. Kline Institute for Psychiatric Research, Orangeburg, NY 10962, USA.

Magnetic Resonance in Medicine
|November 26, 1999
PubMed
Summary
This summary is machine-generated.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Imaging the Internal Auditory Canal with an 8 × 2 Transceiver Array Head Coil at 7T.

AJNR. American journal of neuroradiology·2025
Same author

Transiently increased glutamate cycling in rat PFC is associated with rapid onset of antidepressant-like effects.

Molecular psychiatry·2016
Same author

Selective homonuclear polarization transfer for spectroscopic imaging of GABA at 7T.

Magnetic resonance in medicine·2012
Same author

J-refocused coherence transfer spectroscopic imaging at 7 T in human brain.

Magnetic resonance in medicine·2010
Same author

Hippocampal correlates of pain in healthy elderly adults: a pilot study.

Neurology·2009
Same author

Intracranial EEG power and metabolism in human epilepsy.

Epilepsy research·2009
Same journal

A Comparison of Tissue Property Values Estimated Using Conventional Cardiac MRF and MT-Cardiac MRF.

Magnetic resonance in medicine·2026
Same journal

Dependence of the Extra-Cellular Diffusion Coefficient on the Fractions of Neurites and Cell Bodies in Gray Matter.

Magnetic resonance in medicine·2026
Same journal

Triple-Pulse <sup>23</sup>Na MRI Sequence (TriNa) for Simultaneous Acquisition of Spin-Density-Weighted and Fluid-Attenuated Images.

Magnetic resonance in medicine·2026
Same journal

Evaluation of Phantom Doping Materials in Quantitative Susceptibility Mapping.

Magnetic resonance in medicine·2026
Same journal

Design of an 8-Channel Transmit 32-Channel Receive 11.7T Head Coil and Evaluation of SNR Gains.

Magnetic resonance in medicine·2026
Same journal

The Potential for Absolute Temperature Imaging Based on Brain Metabolites Using an FID-Shifting Approach in Gradient Echo Planar Spectroscopic Imaging (GREPSI).

Magnetic resonance in medicine·2026
See all related articles

A novel automatic slice shimming method enhances magnetic resonance imaging (MRI) by rapidly correcting B(0) field inhomogeneity. This technique improves spectroscopic imaging quality in human brain scans.

Area of Science:

  • Magnetic Resonance Imaging (MRI)
  • Spectroscopic Imaging
  • Medical Physics

Background:

  • B(0) field inhomogeneity is a significant challenge in MRI, affecting image quality and spectral resolution.
  • Accurate shimming is crucial for obtaining high-quality spectroscopic data, especially in vivo.
  • Existing shimming methods can be time-consuming and require manual intervention.

Purpose of the Study:

  • To develop and validate a fast, reliable, and automatic slice shimming method for MRI.
  • To correct in-slice and through-slice B(0) inhomogeneity.
  • To improve the quality of in vivo spectroscopic imaging data.

Main Methods:

  • The method utilizes one-dimensional phase mapping of linear projections through the slice center for in-slice adjustments.

Related Experiment Videos

  • Spherical harmonic terms (first-, second-, and third-order) of B(0) inhomogeneity are determined and corrected.
  • Through-slice shim adjustment is performed using a one-dimensional projection along the slice-selection direction.
  • Main Results:

    • The method successfully determined and corrected all in-slice spherical harmonic terms of B(0) inhomogeneity for axial, coronal, and sagittal slices.
    • Reproducible, high-quality single-slice in vivo spectroscopic imaging data of the human brain were achieved.
    • The automatic shimming process was demonstrated to be fast and reliable.

    Conclusions:

    • The described automatic slice shimming method is effective for correcting B(0) inhomogeneity in MRI.
    • This technique significantly enhances the quality of in vivo spectroscopic imaging, particularly for human brain applications.
    • The method offers a reliable and efficient solution for improving MRI data acquisition.