Related Experiment Videos
Reproducibility of the oxygen uptake efficiency slope in normal healthy subjects
1Tokai University School of Physical Education, Kanagawa, Japan.
Background:
To elucidate the intertest agreement of the oxygen uptake efficiency slope (OUES) in comparison with those of the maximal oxygen uptake (VO2max) and the ventilatory anaerobic threshold (VAT).
Experimental Design:
A comparative study.
Setting:
Institutional practice. A total of 19 healthy volunteers underwent two sessions of maximal exercise testing with an interval of no more than 7 days. The testing was conducted on a cycle ergometer with the work rate increased by either 20, 30, or 40 Watts (W)/min so that the subject would reach exhaustion within 9 to 12 min of exercise. VAT was defined as the level of oxygen uptake (VO2) at which either an increase in the ventilatory equivalent for oxygen without a concomitant increase in the ventilatory equivalent for carbon dioxide or a change in the slope of the linear relationship between carbon-dioxide production (VCO2) and VO2 occurred. OUES was determined by the following equation: VO2 = a log VE + b, where VE was minute ventilation and "a" was the OUES. Intertest reproducibility was assessed by coefficient of repeatability (COR).
Results:
The intertest reproducibility of VO2max and OUES were excellent (COR = 570 ml/min [16%] and 740 [20%], respectively). VAT showed poor agreement between the two tests (COR = 650 ml/min [31%]).
Conclusions:
Results show that OUES is reproducible and reliable, supporting the clinical usefulness of this index.