Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Experiment Videos

An adaptable mechanical multileaf delineator.

L Cozzi1, A Fogliata

  • 1Radio-Oncology Department, Ospedale S. Giovanni, Bellinzona, Switzerland.

Radiotherapy and Oncology : Journal of the European Society for Therapeutic Radiology and Oncology
|December 2, 1999
PubMed
Summary
This summary is machine-generated.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Adjuvant Hypofractionated Whole Breast Irradiation (WBI) vs. Accelerated Partial Breast Irradiation (APBI) in Postmenopausal Women with Early Stage Breast Cancer: 5Years Update of the HYPAB Trial.

Clinical breast cancer·2024
Same author

The pattern of failure after Stereotactic Radiation Therapy (SRT) for oligo-metastases: predictive factors for poly-progression.

Journal of cancer research and clinical oncology·2022
Same author

Long term results of a phase II trial of hypofractionated adjuvant radiotherapy for early-stage breast cancer with volumetric modulated arc therapy and simultaneous integrated boost.

Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology·2021
Same author

The Clean Care Contest: promoting hand hygiene among healthcare and medical students.

Annali di igiene : medicina preventiva e di comunita·2020
Same author

The impact of scanning data measurements on the Acuros dose calculation algorithm configuration.

Radiation oncology (London, England)·2020
Same author

Technical Note: Flattening filter free beam from Halcyon linac: Evaluation of the profile parameters for quality assurance.

Medical physics·2020
Same journal

Definitive IMRT alone with reduced prophylactic nodal irradiation for Early-Stage Oropharyngeal Cancer: JCOG1208.

Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology·2026
Same journal

Associations between body composition and radiotherapy-related side-effects and health-related quality of life in patients with prostate or lung cancer: sub-analysis of the REQUITE trial.

Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology·2026
Same journal

ESTRO recommendations for the use, planning and delivery of reirradiation in locally recurrent rectal cancer - Endorsed by ASTRO.

Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology·2026
Same journal

Early ADC changes in risk-model-defined brain regions precede contrast-enhancing lesions after proton therapy for low-grade glioma.

Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology·2026
Same journal

Any impact of pre-operative radiotherapy on renal function in retroperitoneal soft tissue sarcomas? A secondary ancillary analysis of the EORTC 62092 STRASS 1 trial.

Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology·2026
Same journal

Tumor volume reduction during adaptive radiotherapy is a strong prognostic factor for oropharyngeal cancer: A retrospective multicenter study?

Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology·2026
See all related articles

A new mechanical device aids radiation therapy simulation by accurately imaging patient treatment fields. This accessory ensures precise multileaf collimation field shaping for improved radiation oncology accuracy.

Area of Science:

  • Medical Physics
  • Radiation Oncology
  • Medical Imaging

Background:

  • Accurate simulation is crucial for effective radiation therapy.
  • Current methods for imaging treatment fields can have limitations.

Purpose of the Study:

  • To describe a novel mechanical device for multileaf delineators.
  • To enhance the accuracy of treatment field imaging during radiation therapy simulation.

Main Methods:

  • Design and construction of a mechanical accessory.
  • Mounting the device on a radiation therapy simulator head.
  • Acquiring images of the multileaf collimation shaped field on patient skin.
  • Recording these images on reference X-ray films.

Main Results:

Related Experiment Videos

  • The device reliably images the shaped treatment field on patient skin.
  • Accurate recording of treatment fields on reference X-ray films is achieved.
  • The accessory integrates seamlessly into standard simulation procedures.

Conclusions:

  • The developed mechanical device is a valuable tool for radiation therapy simulation.
  • It improves the reliability and accuracy of treatment field delineation.
  • This innovation supports precise patient-specific radiation oncology planning.