Boron self-shielding effects on dose delivery of neutron capture therapy using epithermal beam and
1Department of Medical Physics, Rush University Medical Center, Chicago, Illinois 60612, USA.
Abstract:
Previous dosimetry studies for boron neutron capture therapy have often neglected the thermal neutron self-shielding effects caused by the 10B accumulation in the brain and the tumor. The neglect of thermal neutron flux depression, therefore, results in an overestimation of the actual dose delivery. The relevant errors are expected to be more pronounced when boronophenylalanine is used in conjunction with an epithermal neutron beam. In this paper, the boron self-shielding effects are calculated in terms of the thermal neutron flux depression across the brain and the dose delivered to the tumors. The degree of boron self-shielding is indicated by the difference between the thermal neutron fluxes calculated with and without considering a 10B concentration as part of the head phantom composition. The boron self-shielding effect is found to increase with increasing 10B concentrations and penetration depths from the skin. The calculated differences for 10B concentrations of 7.5-30 ppm are 2.3%-8.3% at 2.3 cm depth (depth of the maximum brain dose) and 4.6%-17% at 7.3 cm depth (the center of the brain). The additional self-shielding effects by the 10B concentration in a bulky tumor are investigated for a 3-cm-diam spherical tumor located either near the surface (3.3 cm depth) or at the center of the brain (7.3 cm depth) along the beam centerline. For 45 ppm of 10B in the tumor and 15 ppm of 10B in the brain, the dose delivered to the tumors is approximately 10% lower at 3.3 cm depth and 20% lower at the center of the brain, compared to the dose neglecting the boron self-shielding in transport calculations.
Related Concept Videos
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
07:53Measuring the Time-Evolution of Nanoscale Materials with Stopped-Flow and Small-Angle Neutron Scattering
08:34Proton Therapy Delivery and Its Clinical Application in Select Solid Tumor Malignancies
07:51Dielectric RheoSANS — Simultaneous Interrogation of Impedance, Rheology and Small Angle Neutron Scattering of Complex Fluids
09:08Measuring Material Microstructure Under Flow Using 1-2 Plane Flow-Small Angle Neutron Scattering
06:05Using Neutron Spin Echo Resolved Grazing Incidence Scattering to Investigate Organic Solar Cell Materials