Measuring Blood Pressure in Mice using Volume Pressure Recording, a Tail-cuff Method
Published on: May 15, 2009
Direct measurement of intra-cochlear pressure waves
1Physics Department, Princeton University, New Jersey 08544, USA. eolson@princeton.edu
Abstract:
The cochlear travelling wave is fundamental to the ability of the mammalian auditory system to resolve frequency. The seashell-shaped outer bone of the cochlea (the auditory inner ear) contains a spiral of cochlear fluid and the sensory tissue known as the cochlear partition. Sound travels down the ear canal to the eardrum, causing its flexible tympanic membrane to vibrate. This vibration is transmitted to the cochlea via the ossides. Motion of the stapes (the stirrup ossicle) sets the cochlear fluid in motion, which in turn sets the cochlear partition near the states in motion. The motion of the cochlear partition ripples down the cochlear spiral as a travelling wave, stimulating the cochlea's sensory hair cells. The wave peaks near the base (the stapes end) of the cochlea for high frequency tones and near the apex for low frequencies. The fundamental elements of the cochlear travelling wave are fluid pressure and motion and partition forces and motion. However, the wave's direct experimental study has to date relied almost solely on measurements of the partition motion. Here I report finely spaced measurements of intracochlear pressure close to the partition, which reveal the fluid component of the cochlear wave. The penetration depth of the wave is very limited, approximately 15 microm. Over a range of frequencies at least an octave wide, the depth is independent of frequency.
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)
Measurement of Blood Pressure
Measurement of Fluid Pressure
A basic form of manometer is the piezometer, a vertical tube open at the top and filled with the same...