Changes in stroke volume cause change in cardiac output in neonates and infants when mean airway pressure is altered
Related Experiment Video
Updated: Oct 18, 2026

A Swine Model of Neonatal Asphyxia
Published on: October 11, 2011
N Gullberg1, P Winberg, H Selldén
1Pediatric Anesthesia and Intensive Care, Astrid Lindgren Children's Hospital/Karolinska Hospital, Stockholm, Sweden.
Background:
Based on early studies in the lamb, and in spite of more recent studies in humans, it has been the received opinion that neonates and infants can not change their stroke volume significantly, but are mainly dependent on changes in heart rate, to change cardiac output. To further evaluate the relationship between cardiac output and stroke volume during mechanical ventilation of neonates and infants, we have studied the effects on cardiac output and stroke volume by two different ways of changing mean airway pressure.
Methods:
In one group, mean airway pressure was decreased by using a patient triggered mode: pressure support ventilation; in the other, mean airway pressure was increased by increasing positive end-expiratory pressure (PEEP). Changes in cardiac output, heart rate and stroke volume were assessed with the Doppler technique, measuring blood flow velocity in the ascending aorta.
Results:
Without a significant change in heart rate, we found a significant increase in cardiac output of +16+/-2% (P<0.01) with a decrease in mean airway pressure and a decrease in cardiac output of -13+/-4%, (P<0.02) with an increase in mean airway pressure, depicting a change in stroke volume of +17+/-2% (P<0.02) and -14+/-5%, (P<0.01) respectively.
Conclusions:
We conclude that neonates and infants are able to regulate cardiac output by changing the stroke volume to a greater extent than presumed, at least when cardiac output is influenced by changes in the mean airway pressure.
Related Concept Videos
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Regulation of Stroke Volume
Preload refers to the degree of stretch on the heart before it contracts. It's analogous to the stretching of a rubber band; the more it's stretched, the more forcefully it snaps back. This concept is encapsulated in the Frank-Starling law of the...
Pressure Relationships in Thoracic Cavity
Breathing Mechanisms
Both intra-alveolar and intrapleural pressures rely on specific lung properties. The ability to breathe—allowing air to enter the lungs during...
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac output averages...
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart rate...