Design of a Cyclic Pressure Bioreactor for the Ex Vivo Study of Aortic Heart Valves
Published on: August 23, 2011
Feedback control of mean aortic pressure in a dynamic model of the cardiovascular system
D S O'Leary1, G M Pantalos, M K Sharp
1University of Utah, Biofluid Mechanics Laboratory, Salt Lake City 84112, USA.
Abstract:
Orbital measurements of the cardiac function of Space Shuttle crew members have shown an initial increase in cardiac stroke volume upon entry into weightlessness, followed by a gradual reduction in stroke volume to a level approximately 15% less than preflight values. In an effort to explain this response, it was hypothesized that gravity plays a role in cardiac filling. A mock circulatory system was designed to investigate this effect. Preliminary studies carried out with this system on the NASA KC-135 aircraft, which provides brief periods of weightlessness, showed a strong correlation between cardiac filling, stroke volume, and the presence or absence of gravity. The need for extended periods of high quality zero gravity was identified to verify this observation. To accomplish this, the aircraft version of the experiment was reduced in size and fully automated for eventual integration into a Get Away Special canister to conduct an orbital version of the experiment. This article describes the automated system, as well as the development and implementation of a control algorithm for the servoregulation of the mean aortic pressure in the orbital experiment. Three nonlinearities that influence the ability of the apparatus to regulate to a mean aortic pressure of 95 mm Hg were identified and minimized. In preparation for a Space Shuttle flight, the successful function of the servoregulatory scheme was demonstrated during ground tests and additional test flights aboard the KC-135. The control algorithm was successful in carrying out the experimental protocol, including regulation of mean aortic pressure. The algorithm could also be used for the automated operation of long-term tests of circulatory support systems, which may require a scheduled cycling of the pumping conditions on a daily basis.
Related Concept Videos
Blood Pressure
The average BP in an adult is typically around 120/80 mmHg (millimeters of mercury). In this measurement, the numerator (120) indicates the systolic pressure, which is the pressure in the arteries during the contraction of the heart's ventricles as blood is expelled. The denominator (80) represents the diastolic...
Blood Pressure
Measurement of Blood Pressure
Neural Regulation of Blood Pressure
Baroreceptor Reflex
Baroreceptors, located in the carotid sinuses and aortic arch, detect changes in blood pressure. When blood pressure rises, these stretch-sensitive receptors...
Autoregulation of Blood Flow
Chemical Signaling in Autoregulation
Chemical signaling operates at the precapillary sphincter level, inciting either contraction or relaxation.
Aortic Regurgitation I: Introduction