Related Experiment Video
Updated: Jul 22, 2026

Safety Precautions and Operating Procedures in an (A)BSL-4 Laboratory: 2. General Practices
Published on: October 3, 2016
Autoclaves and their dangers and safety in laboratories
Abstract:
Using a laboratory downward displacement vertical autoclave with the help of thermocouples recorded on a 12 point multichannel strip recorder, the risk of failing to sterilize laboratory discard buckets has been demonstrated. The use of proper temperature and time controls can prevent this risk. A load in a bucket with perforated sides is more easily sterilized than in a solid bucket. Wire baskets, where appropriate, facilitate the sterilizing practice. The addition of water to a bucket does not reduce the time of heating up. It is desirable that sealed bottles of media should not be sterilized in simple downward displacement autoclaves, but if used, strict monitoring of temperatures and times is essential both in the heating up stage and especially in the cooling stage. The temperatures in bottles are slow to rise and very slow to fall. Bottles at high temperature 80-105 degrees C. or over have a high internal pressure which can allow the bottles to explode when subjected to thermal shock if removed too early. It is suggested that all laboratory autoclaves should have a load temperature simulator or similar device to control the temperature of the load during the cycle automatically. For the sterilization of fluid media, it is suggested that, in addition to a simulator there should be accelerated cooling to reduce damage to the media and, what is more important, to rapidly bring down the temperature and thus the internal pressure in the bottles to a safe level. The opening of the sterilizer door or lid should be automatically controlled by the load temperature simulator.
Related Concept Videos
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Physical Methods for Controlling Microbial Growth: Temperature
Physical Methods for Controlling Microbial Growth: Radiation and Filtration
Key Techniques in Microbiology