Related Experiment Video
Updated: Oct 2, 2026

Rapid Point-of-Care Assay of Enoxaparin Anticoagulant Efficacy in Whole Blood
Published on: October 12, 2012
Pharmacodynamic activity and antithrombotic efficacy of RPR120844, a novel inhibitor of coagulation factor Xa
R J Leadley1, S R Morgan, R Bentley
1Cardiovascular Drug Discovery, Rhône-Poulenc Rorer International, Collegeville, Pennsylvania 19426, USA. ROBERT.LEADLEY@RP-RORER.COM
Abstract:
These studies were designed to examine the pharmacodynamic profile and antithrombotic efficacy of RPR120844, a competitive inhibitor of coagulation factor Xa, with a K(i) of 7 nM against human factor Xa. In vitro, RPR120844 doubled activated partial thromboplastin time (APTT) at concentrations of 1.54, 1.48, and 0.74 microM in plasma obtained from humans, dogs, and rats, respectively. Intravenous bolus administration of RPR 120844 at 0.3, 1, and 3 mg/kg to rats resulted in maximal increases in APTT of 1.8-, 2.6-, and 8.4-fold over baseline, respectively. The effect on prothrombin time (PT) was less pronounced, resulting in a 4.4-fold increase at 3 mg/kg. These effects were rapidly reversible; APTT and PT returned to control values by 30 min after dosing. Intragastric administration to rats at 50, 100, and 200 mg/kg resulted in modest increases in APTT and PT of 1.5- and 1.3-fold over baseline at the highest dose. Plasma levels were estimated by anti-Xa activity by using an amidolytic, chromogenic assay. Plasma levels were 0.65, 1.29, and 2.45 microM at 30 min after dosing at 50, 100, and 200 mg/kg, respectively. Intravenous administration to dogs at 0.1 and 0.3 mg/kg produced maximal increases in APTT of 1.7- and 2.4-fold over baseline, respectively. Intragastric administration to dogs at 50 mg/kg resulted in maximal increases in APTT and PT of 1.7- and 1.1-fold over baseline, with peak plasma levels of 3.9 microM observed at 15 min after dosing. In a rat model of FeCl2-induced carotid artery thrombosis, RPR120844 (3 mg/kg, i.v. bolus + 300 microg/kg/min constant infusion; n = 4) significantly increased time-to-occlusion from 18+/-1 min (vehicle, n = 4) to 60 min (maximal observation time) and reduced thrombus mass from 5.5 +/- 0.2 mg (vehicle) to 1.4 +/- 0.2 mg. These results indicate that RPR120844 is a potent, selective inhibitor of Xa that exhibits oral activity and is efficacious in a standard model of arterial thrombosis.
More Related Videos
Related Concept Videos
Anticoagulant Drugs: Low-Molecular-Weight Heparins
Anticoagulant Drugs: Vitamin K Antagonists and Direct Oral Anticoagulants
Warfarin, a prominent vitamin K antagonist family member, exerts its effect by inhibiting the enzyme VKORC1 (vitamin K epoxide reductase complex 1). By hindering this enzyme, warfarin...
Antiplatelet Drugs: Prostaglandin Synthesis, P2Y12 and Glycoprotein IIb/IIIa Inhibitors
Prostaglandin synthesis inhibitors, exemplified by the widely known aspirin, wield their power by irreversibly acetylating...
Treatment for Pulmonary Arterial Hypertension: Prostacyclin Receptor Agonists
These agonists bind to the IPR receptor situated on the plasma membrane of the pulmonary artery smooth muscle cells. This binding triggers a cascade of reactions known as the GS-AC-cAMP-PKA pathway. This pathway results in the relaxation of smooth muscle...
Pharmacokinetic–Pharmacodynamic Relationship: Problems
Venous Thrombosis III: Interprofessional Care