Related Experiment Video
Updated: Aug 1, 2026

Confocal Time Lapse Imaging as an Efficient Method for the Cytocompatibility Evaluation of Dental Composites
Published on: November 9, 2014
Evaluating the potential occupational hazard of handling dental polymer products using the HET-CAM technique
E C Lönnroth1, J E Dahl, H Shahnavaz
1Department of Human Work Sciences, Luleå University of Technology, Sweden. emma@arb.luth.se.
Abstract:
The irritation potencies of 8 dental polymer products, used as dental restorative materials, adhesives, or temporary constructions, were tested using the HET-CAM (hen's egg test-chorioallantoic membrane) technique. Liquid and powder components, and extracts of cured and freshly mixed non-cured materials of 5 glass ionomers, 1 bonding, 1 composite, and 1 cold-cured acrylate were examined. Results showed that the liquid component of all products had a strong irritation capacity but powder suspensions and extracts from cured and freshly mixed non-cured materials had no effect on the CAM. Thus, dental personnel who handle liquid and powder manually are exposed to components with a high irritation potential, in contrast to patients who are exposed to the cured and mixed non-cured materials with low irritation potential. This illustrates the importance of safe handling procedures and practices for dental personnel who handle non-cured polymers manually.
More Related Videos
05:30Roughness Impact of Piezoelectric Dental Scaler on Two Distinct Flowable Composite Filling Materials
Published on: January 10, 2025
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024