A Model to Simulate Clinically Relevant Hypoxia in Humans
Published on: December 22, 2016
Non-invasive measurement of haemodynamics during sleep apnoea
Abstract:
Sleep apnoeas are accompanied by large variations in heart rate (HR) and blood pressure (BP). This nocturnal variability in BP may be involved in the increased cardiovascular morbidity of these patients. Due to the complex interaction between asphyxia, intrathoracic pressure, cardiac function and autonomic activation, the exact haemodynamic mechanisms are unclear. To evaluate the components of the BP surges at resumption of breathing (RB) a non-invasive beat-to-beat measurement was taken of cardiac output (CO) by the pulse contour analysis of the Finapres signal. Six male normotensive patients, free of medication (37-60 y, BMI 26.5-43.0 kg m-2) were studied during polysomnography (apnoea index: 22-69 h-1). Systolic blood pressure rose from 126.5 +/- 1.3 mmHg at beginning apnoea (P1) to 140.4 +/- 1.3 at RB (P < 0.01, ANOVA). During sleep Stages 2 and 3, stroke volume decreased during RB to 96% of P1 value (NS). Due to an opposite change in HR, CO tended to rise at RB to 106% of P1. Computed total peripheral resistance rose during RB to 105% of P1 value (P < 0.011. Therefore, it is concluded that the surge in BP at RB after apnoea is due to concomitant increases in CO and in TPR. Both rises are presumably a consequence of sympathetic nervous activation by the arterial chemoreceptors.
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Measurement of Blood Pressure
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...