Related Experiment Video
Updated: Jul 8, 2026

Use of Label-free Optical Biosensors to Detect Modulation of Potassium Channels by G-protein Coupled Receptors
Published on: February 10, 2014
Atomic scale movement of the voltage-sensing region in a potassium channel measured via spectroscopy
A Cha1, G E Snyder, P R Selvin
1Department of Physiology, UCLA School of Medicine, Los Angeles, California 90095, USA.
Abstract:
Voltage-gated ion channels are transmembrane proteins that are essential for nerve impulses and regulate ion flow across cell membranes in response to changes in membrane potential. They are made up of four homologous domains or subunits, each of which contains six transmembrane segments. Studies of potassium channels have shown that the second (S2) and fourth (S4) segments contain several charged residues, which sense changes in voltage and form part of the voltage sensor. Although these regions clearly undergo conformational changes in response to voltage, little is known about the nature of these changes because voltage-dependent distance changes have not been measured. Here we use lanthanide-based resonance energy transfer to measure distances between Shaker potassium channel subunits at specific residues. Voltage-dependent distance changes of up to 3.2 A were measured at several sites near the S4 segment. These movements directly correlated with electrical measurements of the voltage sensor, establishing the link between physical changes and electrical charge movement. Measured distance changes suggest that the region associated with the S4 segment undergoes a rotation and possible tilt, rather than a large transmembrane movement, in response to voltage. These results demonstrate the first in situ measurement of atomic scale movement in a trans-membrane protein.
More Related Videos
Related Concept Videos
The Role of Ion Channels in Neuronal Computation
Sometimes a single EPSP is strong enough to induce an action potential in the postsynaptic neuron. However, multiple presynaptic inputs must often create EPSPs around the same time for the postsynaptic neuron to be sufficiently depolarized to fire an action potential.
Voltage-gated Ion Channels
Generally, all voltage-gated ion channels have a 'voltage-sensing domain' that spans the lipid bilayer. The charged residues in the sensor move in response to the membrane potential changes that open the channel allowing ions movement. There are several types of...
Mechanically-gated Ion Channels
Voltammetric Techniques: Linear-Scan (E vs Time)
Voltage-gated Ion Channels
Generally, all voltage-gated ion channels have a 'voltage-sensing domain' that spans the lipid bilayer. The charged residues in the sensor move in response to the membrane potential changes that open the channel allowing ions movement. There are several types of...
Mechanically-gated Ion Channels