Cone-beam computed tomography with a flat-panel imager: effects of image lag
1Department of Radiation Oncology, William Beaumont Hospital, Royal Oak, Michigan 48073, USA. jsiewerd@beaumont.edu
Abstract:
A system for cone-beam computed tomography (CBCT) has been developed based upon the technology of active matrix flat-panel imagers (FPIs), and the system has demonstrated the potential for fully three-dimensional volumetric imaging with high spatial and contrast resolution. This paper investigates the effects of image lag (arising from charge trapping and release in the FPI pixels) upon CBCT reconstructions. Hypotheses were derived based upon a simple, geometrical/physical model, suggesting that image lag in the projection data results primarily in two artifacts: a spatial blurring artifact in the direction opposite to the direction of rotation (called a "comet") and a line artifact along the direction of the first few projections (called a "streak"). The hypotheses were tested by means of computer simulations and experimental measurements that yielded CBCT images of a simple cylindrical water phantom containing an attenuating rod of varying size and composition. The computer simulations generated projection images based upon analysis of the system geometry and a simple model of the FPI that allowed free adjustment of the image lag. Experimental measurements involved CBCT scans of the phantom under various conditions and modes of acquisition followed by examination of the resulting CBCT axial slices for lag artifacts. Measurements were performed as a function of exposure level, position and contrast of the rod, and for three modes of acquisition designed to isolate and/or minimize the two hypothesized artifacts. The results clearly illustrate the comet and streak artifacts, particularly in relation to high-contrast objects imaged at high exposure levels. The significance of such artifacts under clinical conditions is expected to be small, considering the magnitude of the effect relative to the morphology and composition of typical anatomy. The artifacts may become appreciable, however, in the presence of high-contrast objects, such as marker BBs, dental fillings, and metal prosthetics. A procedural method of reducing lag artifacts is demonstrated.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies III: Computed Tomography