Related Experiment Video
Updated: Oct 14, 2026

Determining heat and mechanical pain threshold in inflamed skin of human subjects
Published on: January 13, 2009
Reliability and normal values for measuring the skin temperature of the hand with an infrared tympanic thermometer: a
H M Oerlemans1, M J Graff, J B Dijkstra-Hekkink
1Allied Health Services, University Hospital Nijmegen, The Netherlands.
Abstract:
Recording asymmetry in skin temperature between symmetric body areas is useful in monitoring diseases that alter skin temperature. This pilot study checked the reported high reliability of recording skin temperature of the hands with an infrared tympanic thermometer, provided insight into the relationship between dorsal and palmar temperature differences, and assessed the agreement between these data and normative data obtained from thermograms. Using an infrared tympanic thermometer, two independent assessors measured the temperature of 13 asymptomatic, right-handed subjects (mean age, 30 years; range, 21 to 44 years). Both test-retest and interobserver reliabilities were high. Skin temperature of the hand differed with the site where it was measured; differences between sites changed over time. The mean absolute differences in skin temperature between dorsal and palmar aspects of the hands were 0.30 degrees C and 0.25 degrees C, respectively. These data match normative values reported in the literature for infrared thermograms.
Related Concept Videos
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...

