Characteristics of different nucleic acid staining dyes for DNA fragment sizing by flow cytometry

X Yan1, W K Grace, T M Yoshida

  • 1Life Sciences Division, Los Alamos National Laboratory, New Mexico 87545, USA.

Analytical Chemistry
|January 7, 2000
PubMed

Related Concept Videos

DNA Agarose Gel Electrophoresis02:35

DNA Agarose Gel Electrophoresis

Agarose gel electrophoresis is a laboratory technique commonly used to separate DNA fragments by size. However, it can also be used to isolate and purify DNA fragments using a gel extraction protocol.
Gel extraction follows five major steps: running gel electrophoresis to separate fragments, isolating the individual bands, extracting DNA from those bands, and removing the dye and salts from the extracted mixture to obtain pure DNA.
In cloning experiments, both the insert and vector DNA...
Labeling DNA Probes03:31

Labeling DNA Probes

DNA probes are fragments of DNA labeled with a reporter tag to enable their detection or purification. The resulting labeled DNA probes can then hybridize to target nucleic acid sequences through complementary base-pairing, and may be used to recover or identify these regions.
Radioisotopes, fluorophores, or small molecule binding partners like biotin or digoxigenin, are the most widely used reporter tags for labeling DNA probes. These labels can be attached to the probe DNA molecule via...
Southern Blot02:57

Southern Blot

Agarose gel electrophoresis is very useful in separating DNA fragments by size. Running a DNA ladder containing fragments of the known length alongside the sample helps determine the approximate length of the sample DNA fragments. However, additional steps are needed to verify the sequence identity of the sample DNA fragments.
Denatured DNA fragments must be transferred onto a carrier membrane from the gel to make it accessible to a probe - a small ssDNA fragment complementary to the target DNA...
Flow Cytometry01:23

Flow Cytometry

The development of flow cytometry techniques began in 1934 with initial attempts by Andrew Moldavan, a bacteriologist who counted the cells in a flowing capillary system. Moldavan pumped cells through a capillary tube focused under a microscope for visualization. The invention of photometry allowed the measurement of differentially-stained cells, and Louis Kamentsky developed the first multiparameter flow cytometer in 1965 to identify and count the cancer cells in cervical tissue specimens.
In...
Fixation and Sectioning01:03

Fixation and Sectioning

Two basic types of preparation are used to visualize specimens with a light microscope: wet mounts and fixed specimens.
The simplest type of preparation is the wet mount, in which the specimen is placed in a drop of liquid on the slide. A liquid specimen can be directly deposited on the slide using a dropper. Solid specimens, such as skin scraping, can be placed on the slide before adding a drop of liquid to prepare the wet mount. Sometimes the liquid is simply water, but stains are often added...