Improvement in the cervical mucus penetration test by using standard sperm control
1Institute for the Study of Fertility, Lis Maternity Hospital, Tel Aviv Sourasky Medical Center, Sackler Faculty of Medicine, Tel Aviv University, Israel.
Archives of Andrology
|January 7, 2000
Summary
The cervical mucus penetration test (CMPT) requires a minimal progressive motile spermatozoa concentration (PMSC) of 14 x 10(6)/mL for optimal results. Freeze-thawing sperm samples does not impact CMPT outcomes, supporting cryopreservation for future use.
Area of Science:
- Reproductive Biology
- Andrology
- Sperm Analysis
Background:
- The cervical mucus penetration test (CMPT) is crucial for evaluating sperm function.
- Establishing standardized conditions for CMPT, particularly sperm concentration, is essential for reliable results.
- The impact of sperm processing, such as freeze-thawing, on CMPT performance needs clarification.
Purpose of the Study:
- To determine the minimal progressive motile spermatozoa concentration (PMSC) yielding the highest CMPT score.
- To compare CMPT performance using fresh versus frozen-thawed sperm specimens.
- To establish an acceptable standard for the CMPT.
Main Methods:
- Semen was collected from 29 fertile donors.
- Progressive motile spermatozoa concentration (PMSC) was adjusted to 8, 10, and 14 x 10(6)/mL for fresh and frozen-thawed samples.
- Each sperm sample dilution was tested against the same cervical mucus specimen.
Main Results:
- No significant difference was observed in CMPT scores between fresh and frozen-thawed sperm samples.
- Sperm specimens with a PMSC of 14 x 10(6)/mL consistently achieved the highest CMPT scores.
- A minimal PMSC of 14 x 10(6)/mL is recommended for reliable CMPT results.
Conclusions:
- The minimal progressive motile spermatozoa concentration (PMSC) required for optimal CMPT performance is 14 x 10(6)/mL.
- Cryopreservation does not adversely affect sperm performance in the CMPT.
- Pooled, cryopreserved fertile donor sperm specimens can be utilized as a standardized control for CMPT.