Related Experiment Video
Updated: Aug 18, 2026

Scanning Electron Microscopic Evaluation of Surface Defects of Remover Retreatment File After Single and Multiple Uses
Published on: October 11, 2024
Effect of experience on quality of canal preparation with rotary nickel-titanium files
1Department of Operative Dentistry and Periodontology, Dental School, University of Cologne, Germany.
Objective:
The purpose of this study was to compare inexperienced third-year dental students and experienced dentists with respect to their ability to use rotary nickel-titanium files, specifically with respect to root canal shape and instrument fracture.
Study Design:
A total of 102 simulated endodontic plastic blocks were used. Twelve untrained dental students and 12 practitioners prepared 3 blocks each, and an endodontist and a trained student completed 15 blocks each. Blocks were filmed before instrumentation and then prepared to ISO 35; they were filmed again after canal preparation. Before-preparation images and after-preparation images were then superimposed. The canal deviation during preparation was measured at 9 levels, beginning at the apex.
Results:
In total, 16 of 170 instruments fractured (9.4%). Nearly all preparations (98%) exhibited good taper, smooth walls, and definite apical stops. Material removal on the outer aspect of the canal was greatest near the apex (levels 1-4: 0.11-0.24 mm). The inner aspect of the canal was most instrumented at level 6 (0.23-0.27 mm).
Conclusions:
These findings show that both students lacking endodontic experience and experienced dentists used the rotary nickel-titanium files with success and achieved good root canal geometry.