Measuring forces and frequency during active compression decompression cardiopulmonary resuscitation: a device for training, research and real CPR
Related Experiment Video
Updated: Oct 18, 2026

Integrated Compensatory Responses in a Human Model of Hemorrhage
Published on: November 20, 2016
1Department of Anaesthesia and Institute for Emergency and Disaster Medicine, The Leopold-Franzens-University of Innsbruck, Austria.
Abstract:
Active compression decompression (ACD) cardiopulmonary resuscitation (CPR) is possibly a superior alternative to standard (STD) CPR, but an optimal compression and decompression pattern has to be ensured. ACD-CPR can be evaluated during CPR training sessions using commercially available manikins; however devices for recording compression and decompression forces or frequency during real CPR are lacking. Using the Ambu CardioPump without changing its mechanical characteristics, two force transducers were integrated into the ACD device. Using specially designed electronics and a portable computer, compression and decompression forces were measured and displayed continuously and compression frequency and the compression decompression phase are calculated on-line during real CPR action. All measured parameters were stored on a hard disk for later retrieval and analysis. Linearity of force measurement was better than 6% within a -250- +500 N range. The error in repeatability was below 5% thus outperforming the original mechanical force measurement system of the Ambu CardioPump. Compression frequency was calculated very accurately (error < 1%). The system has been successfully used during CPR training, during ACD-CPR in 37 corpses under research conditions and in five out-of-hospital CPR casualties. Simple and safe in use, our modified CardioPump with integrated electronics provides an important, technically advanced solution for monitoring ACD-CPR on-line. It warrants quality assurance during ACD-CPR training and in real CPR scenarios and guarantees accurate recording of compression and decompression forces and compression frequency.
Related Concept Videos
Cardiopulmonary Resuscitation I: Adult
Cardiopulmonary Resuscitation III: AED Use
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Cardiopulmonary Resuscitation II: ACLS Airway Management