Related Experiment Video
Updated: Aug 11, 2026

Non-invasive Optical Measurement of Cerebral Metabolism and Hemodynamics in Infants
Published on: March 14, 2013
Evaluation of accuracy of pulse oximetry in newborn calves
C H Uystepruyst1, J Coghe, F Bureau
1Laboratory for Functional Investigation, Department of Large Animal Clinical Sciences, Faculty of Veterinary Medicine, University of Liège, Belgium. christophe.uystepruyst@ulg.ac.be
Abstract:
In human medicine, pulse oximetry is widely used to measure non-invasively and accurately the percentage of oxygen saturation of arterial haemoglobin (SpO(2)). Recently, pulse oximetry has been used in calves, but its accuracy has not been evaluated in newborn calves. The purpose of this study was to evaluate the accuracy of a pulse oximeter in newborn calves by comparing SpO(2) with arterial oxyhaemoglobin saturation (SaO(2)) obtained by use of a blood gas analyser. Fifty-five newborn calves were investigated from birth to 20 days old. Pulse oximetry readings and arterial blood samples were performed 5, 15, 30, 45, 60 min, 2, 3, 6, 12, 24 h and 1 and 3 weeks after birth. The transmission-type sensors of the pulse oximeter were fixed at the recommended site in the bovine species (at the base of the calf tail, where the skin had been shaved and was not pigmented) and arterial blood samples were withdrawn from the subclavian artery and analysed for SaO(2). Five-hundred paired data of SaO(2) and mean SpO(2)(mSpO(2)) were collected. Linear regression of the pooled data indicated a highly significant correlation of mSpO(2) with SaO(2) (r = 0.87;P< 0.001; mSpO(2) = 15.8 + 0.84 SaO(2)). The overall data bias value was positive (+2.1%), which indicated that the pulse oximeter tended to overestimate the SaO(2). The bias value for each SaO(2) category tended to become higher for lower ranges of SaO(2). Precision was also lower when SaO(2) values were low. The lower the SaO(2) value, the higher the positive bias (overestimation) and the lower the precision. These results suggest that pulse oximetry provides a relatively accurate non-invasive, immediate and portable method to monitor SaO(2) and to evaluate objectively the pulmonary function effectiveness in newborn calves during their adaptation to extra-uterine life.
Related Concept Videos
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Special considerations while measuring pulse
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...

