Related Experiment Videos
The wire interlock technique for harvesting a partial-width distally attached tendon graft
B Lester1, R R McCormack, G K Jeong
1Department of Orthopaedic Surgery, Montefiore Medical Center, Bronx, NY 10461, USA.
The Journal of Hand Surgery
|January 22, 2000
Abstract:
A wire interlock technique useful for harvesting a partial-width tendon graft with an intact insertion for local reconstructive procedures is described. This technique is rapid and reliable for procuring attached tendon grafts with minimal exposure. The technique was used to harvest a flexor carpi radialis tendon graft for basal joint interposition arthroplasty in 12 patients. This method also may be readily applicable for other procedures requiring local ligament reconstruction with a partial-width tendon graft. (J Hand Surg 2000; 25A:176-182.