Related Experiment Video
Updated: Aug 15, 2026

DUCT: Double Resin Casting followed by Micro-Computed Tomography for 3D Liver Analysis
Published on: September 28, 2021
Liver and bone window settings for soft-copy interpretation of chest and abdominal CT
S M Pomerantz1, C S White, T L Krebs
1Department of Diagnostic Imaging, University of Maryland Medical System, Baltimore 21201, USA.
Objective:
We evaluated whether the use of multiple window and level settings on a soft-copy workstation improves diagnostic accuracy on chest and abdominal CT. We hypothesized that routinely using window and level settings during soft-copy interpretation would beneficially affect the final diagnosis without compromising efficiency.
Materials And Methods:
Two hundred three randomly selected abdominal and chest CT scans were interpreted by three radiologists using a four-monitor soft-copy workstation (images per screen, nine; resolution, 2K). After the initial interpretations, all scans were reevaluated by the same radiologists using additional liver and bone window and level settings. Differences in conspicuity and characterization of abnormalities were graded on a three-point scale.
Results:
Conspicuity and characterization of abnormalities were improved in 67% of abnormal findings (81/121; p = 0.01). Improvement (a finding that substantially affected the final diagnosis) was present in 18% of abnormal findings (22/121; p = 0.04). On average, the evaluation of images at multiple window and level settings required an additional 40 sec per case.
Conclusion:
The use of multiple window and level settings during soft-copy interpretation resulted in improved lesion detectability and characterization with greater diagnostic efficacy. Using soft-copy workstations, radiologists can evaluate images using multiple settings without compromising efficiency.
Related Concept Videos
X-ray Imaging
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Ultrasonography
During an ultrasonography procedure, a handheld device called a...
Radiological Investigation I: X-ray and CT
Imaging Studies for Cardiovascular System V: CT