Related Experiment Video
Updated: Feb 19, 2026

Calibration Procedures for Orthogonal Superposition Rheology
Published on: November 18, 2020
Use of weighted least-squares splines for calibration in analytical chemistry
1Faculty of Mathematics and Computer Science, Babes-Bolyai University, Cluj-Napoca, Romania.
Abstract:
Weighted least-squares spline functions are discussed and applied for calibration processes in analytical chemistry. Different weighting techniques are also considered, and for the evaluation of the results some quality coefficients are proposed. Depending upon the structure of the data, some weighting procedures may improve the results dramatically. Considering the results obtained in the case of TLC densitometry, it seems that nonlinear weighting procedures based upon the distance to the function are the best ones, with a plus for the y-distance type. It is difficult to give general rules regarding the optimal parameters of the weighted calibration splines-function order (m), number (N) and distribution of knots, and weighting technique. These depend upon the structure of the data. However, higher order splines are not recommended since the result might become extremely unstable. The example used to illustrate the performances of the procedures discussed here involved only a single independent variable. The method is general and extends practically to any number of variables, thus resulting in a multivariate approach.
More Related Videos
10:22Split Point Analysis and Uncertainty Quantification of Thermal-Optical Organic/Elemental Carbon Measurements
Published on: September 7, 2019
08:37Measurement of H2S in Crude Oil and Crude Oil Headspace Using Multidimensional Gas Chromatography, Deans Switching and Sulfur-selective Detection
Published on: December 10, 2015
Related Concept Videos
Calibration Curves: Linear Least Squares
For data that follow a straight line, the standard method for fitting is the linear...
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Calibration Curves: Correlation Coefficient
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Quantitative Analysis
In quantitative analysis, two key measurements are made: the sample quantity and a property proportional to the amount of the analyte (the substance being analyzed). This forms the basis of the...
Calculating Equilibrium Concentrations
A more...