Related Experiment Videos
Bronchoscopic removal of an inhaled, sharp, foreign body: an unusual complication
1Department of Surgery, Northampton General Hospital, UK.
The Journal of Laryngology and Otology
|February 9, 2000
Abstract:
A case is reported in which an inhaled sewing needle, stuck fast in the trachea, became displaced through the tracheal wall during attempted removal via flexible bronchoscopy. The inherent risks and pitfalls of this procedure are highlighted.