Related Experiment Video
Updated: Aug 10, 2026

Magnetic Resonance Imaging Assessment of Carcinogen-induced Murine Bladder Tumors
Published on: March 29, 2019
Serial CT and MR imaging of carmustine wafers
J M Prager1, Y Grenier, J W Cozzens
1Department of Radiology, Evanston Northwestern Healthcare, IL 60201, USA.
Background And Purpose:
A new option in the treatment of recurrent malignant glioma is surgical placement of chemotherapy-laden biodegradable wafers. We describe the CT and MR appearance of chemotherapy wafers in patients after surgery for recurrent malignant glioma
Methods:
Eighteen patients had carmustine (BCNU) wafers implanted during reoperation for malignant glioma; three patients had empty, placebo wafers placed. The 21 patients had a total of 22 CT and 57 MR imaging studies. Repeat CT studies were conducted for up to 6 months, the MR studies for up to 1 year. Examinations were evaluated for attenuation on CT scans, signal abnormalities on MR images, and changing appearance during the follow-up period. Enhancement characteristics were also assessed.
Results:
On CT scans, 13 of 16 acute (<7 days) cases showed linear high-attenuation wafers, with three showing low attenuation. On MR images, all T1 and T2 studies performed in the acute stage showed decreased signal of the wafers. Eight of 15 studies showed a transient increase in T1 only at about 2 months. Wafers decreased in conspicuity on both CT and MR studies after 2 months. The wafers did not enhance. One postoperative tumor showed a transient increase in edema and increased enhancement at 5 weeks. The presence or absence of BCNU within the wafers did not change their appearance.
Conclusion:
BCNU wafers have a characteristic appearance: in the first 7 days after implantation they are linear, usually of increased attenuation on CT scans, and always show decreased signal on MR images; they do not enhance, and become less conspicuous after 2 months.
More Related Videos
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies for Cardiovascular System V: CT
Imaging Studies III: Computed Tomography