Determination of the thermodynamic contribution to peak asymmetry of basic solutes in reversed-phase liquid
1Department of Chemistry, California State University, San Bernardino 92407-2397, USA.
Abstract:
To this day packing materials manufacturers are still trying to develop reversed-phase stationary phases that have silica more completely reacted with bonding ligands to afford more homogeneous particle surfaces. Incomplete bonding causes inhomogeneous effects that are readily observed when separating basic solutes because of the acidic silanols that are unreacted. However, it is still not understood exactly what types of silanol sites are unreacted or if metal impurities are contributing to the resulting peak asymmetry observed. A method is presented which utilizes (1) the frontal analysis method of chromatography to obtain adsorption/partition isotherms, (2) a heterogeneous Langmuir distribution model for the resulting isotherm, (3) an expectation-maximization numerical procedure to solve the mathematical problem to yield the most probable distribution of adsorption parameters, and (4) the equilibrium-dispersive model of chromatography incorporating the fitted isotherm model to check the validity of the sorption model with experimental observations. Correlation of packing materials characterization parameters with results obtained by this procedure will indicate what type of silanols or other sites are responsible for observed tailing behavior. Developers and manufacturers will then be able to more efficiently target their synthetic designs for "base-deactivated" reversed-phase silicas.
Related Concept Videos
Analyte Adsorption and Distribution
Chromatographic Methods: Terminology
High-Performance Liquid Chromatography: Elution Process
Chromatographic Resolution
The effectiveness of separation can be evaluated by determining the level of separation between two neighboring peaks in a chromatogram, which represents the individual components of a sample.
In chromatography,...
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Column Efficiency: Rate Theory