Related Experiment Videos
Rapid MR imaging of cryoprotectant permeation in an engineered dermal replacement
N P Bidault1, B E Hammer, A Hubel
1Department of Biomedical Engineering, University of Minnesota, Minneapolis, Minnesota 55455, USA.
Abstract:
Magnetic resonance (MR) imaging is a powerful technique for monitoring the permeation of cryoprotective agents (CPAs) inside tissues. However, the techniques published until now suffer from inherently long imaging times, limiting the application of these techniques to slow diffusion processes and large CPA concentrations. In this study, we present a rapid MR imaging technique based on a CHESS-FLASH scheme combined with Keyhole image acquisition. This technique can image the fast permeation of Me(2)SO solutions into freeze-dried artificial dermal replacements for concentrations down to 10% v/v. Special attention is given to evaluating the technique for quantitative analysis.