Abstract:
We investigated the intrinsic (as delivered by the manufacturer) and routine quality of four systems for measurement of serum total magnesium (t-Mg(2+)) by method comparison with an ion chromatography reference method. The results of the study were interpreted on the basis of analytical quality specifications derived from the biological variation of t-Mg(2+), expanded by the analytical uncertainty of the reference measurements. This resulted in limits for systematic error of 2.1% and for total error of 4.3%. The study demonstrated that those limits were challenging for all routine systems. Most of them met the total error criterium just borderline and one showed a considerable systematic error (-5.2%). Concerning the measurement quality in the routine laboratories, the study showed that many were unable to preserve the intrinsic quality of the respective manufacturer. Consequently, loss of system performance in the routine laboratory mostly led to violation of the analytical specifications. Most strikingly, the study revealed enormous quality differences between routine laboratories. This indicates that, still, many routine laboratories do not make adequate use of currently available internal and external quality control tools. Moreover, some laboratories considerably expanded the high end of the reference interval, thereby reducing the diagnostic potential of t-Mg(2+).
Related Concept Videos
Complexometric Titration: Overview
EDTA: Direct, Back-, and Displacement Titration
Direct titration involves buffering the metal ion solution to the desired pH and directly titrating with standard EDTA until the endpoint. The optimum pH ensures a large conditional formation constant of metal−EDTA and visibility of the free indicator color in the solution. In addition, auxiliary complexing reagents are used to prevent the precipitation of metal hydroxides and...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...
EDTA: Indirect and Alkalimetric Titration
Serum Studies: Renal Function Tests