Abstract:
We have measured pressure changes in a newly designed tracheal tube cuff, the Portex Soft Seal, during nitrous oxide anaesthesia compared with a Mallinckrodt Lo-Contour tube and a Portex Profile tube. The pressure increases in both control groups were significantly greater than those with the new design (P < 0.0001 in each case). The mean increase in pressure in the Mallinckrodt Lo-Contour tube cuff was 9.9 (SD 3.4) mm Hg compared with 10.3 (1.8) mm Hg in the Portex Profile tube cuff and 2.1 (1.5) mm Hg in the Portex Soft Seal tube cuff. We conclude that the Portex Soft Seal cuff prevented a significant increase in intracuff pressure during nitrous oxide anaesthesia.
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...