V L Hoffmann1, M P Vercauteren, J P Vreugde
1Department of Anaesthesiology, University Hospital Antwerp, Edegem, Belgium.
British Journal of Anaesthesia
|February 26, 2000
Abstract:
We have compared skin to epidural space distance (SED) and tip to tip distance (TTD), a measure of posterior epidural space depth (PESD), in 40 patients with a 27-gauge Whitacre needle after identification of the epidural space using the hanging drop (HD) or loss of resistance (LOR) to air technique. After the LOR technique, TTD was found to be 2 mm greater than that after the HD technique, whereas SED was the same. We conclude that identification of the epidural space can be performed successfully with both techniques, but with a diminished risk of dural damage after LOR compared with the HD technique.