Quantitative spectral/spatial analysis of phased array coil in magnetic resonance imaging based on method of moment

F H Lin1, W P Kuan, S K Jeng

  • 1Program of Medical Engineering and Medical Physics, Harvard University, Cambridge, MA 02138, USA.

Related Concept Videos

Magnetic Resonance Imaging01:24

Magnetic Resonance Imaging

Magnetic resonance imaging (MRI) is a noninvasive medical imaging technique based on a phenomenon of nuclear physics discovered in the 1930s, in which matter exposed to magnetic fields and radio waves was found to emit radio signals. In 1970, a physician and researcher named Raymond Damadian noticed that malignant (cancerous) tissue gave off different signals than normal body tissue. He applied for a patent for the first MRI scanning device in clinical use by the early 1980s. The early MRI...
NMR Spectrometers: Resolution and Error Correction01:14

NMR Spectrometers: Resolution and Error Correction

When magnetic nuclei in a sample achieve resonance and undergo relaxation, the signal detected in NMR is an approximately exponential free induction decay. Fourier transform of an exponential decay yields a Lorentzian peak in the frequency domain. Lorentzian peaks in an NMR spectrum are defined by their amplitude, full width at half maximum, and position, where the peak width is governed by the spin-spin relaxation time alone. In real experiments, however, the applied magnetic field is rendered...
Paramagnetism01:30

Paramagnetism

Paramagnets are materials with unpaired electrons that possess a finite magnetic moment. In the absence of a magnetic field, these moments are randomly oriented, and thus the net moment is zero. Under an external field, a torque acting on the moments tends to align them along the field's direction. However, the random thermal motion of electrons produces a torque opposite to the external field and tries to disorient the moments. These two competing effects align only a few moments along the...
Atomic Nuclei: Magnetic Resonance01:05

Atomic Nuclei: Magnetic Resonance

The number of nuclear spins aligned in the lower energy state is slightly greater than those in the higher energy state. In the presence of an external magnetic field, as the spins precess at the Larmor frequency, the excess population results in a net magnetization oriented along the z axis. When a pulse or a short burst of radio waves at the Larmor frequency is applied along the x axis, the coupling of frequencies causes resonance and flips the nuclear spins of the excess population from the...
Diamagnetism01:26

Diamagnetism

Materials consisting of paired electrons have zero net magnetic moments. However, when these materials are placed under an external magnetic field, the moments opposite to the field are induced. Such materials are called diamagnets. Diamagnetism is the response of the diamagnets when placed in an external magnetic field.
Diamagnetism was discovered by Anton Brugmans in 1778 when he observed that bismuth gets repelled by magnetic fields, thus theorizing that diamagnets get repelled by magnets.
Potential Due to a Magnetized Object01:24

Potential Due to a Magnetized Object

Magnetic dipoles in magnetic materials are aligned when placed under an external magnetic field. For paramagnets and ferromagnets, dipole alignment occurs in the direction of the magnetic field. However, the dipoles align opposite to the field in the case of diamagnets. This state of magnetic polarization due to the external field is called magnetization. Magnetization is defined as the dipole moment per unit volume. It plays a similar role to polarization in electrostatics.
The vector...