Chromatographic and UV-VIS and IR spectral methods for qualitative and quantitative analysis of some synthetic bromo-flavone derivatives
Related Experiment Video
Updated: Oct 17, 2026

09:46
Qualitative Identification of Carboxylic Acids, Boronic Acids, and Amines Using Cruciform Fluorophores
Published on: August 19, 2013
M I Lazar1, D Lazar, E Diaconu
1University of Medicine and Pharmacy, Department of Drugs Control, Iasi, Romania. mlazar@asklepios.umfiasi.ro
Journal of Pharmaceutical and Biomedical Analysis
|March 4, 2000
Abstract
No abstract available in PubMed .
Related Concept Videos
Chromatographic Methods: Classification
Chromatographic techniques are classified in three ways: the classification is based on the physical state of the stationary and mobile phases, how the mobile phase and the stationary phase contact each other, or through the chemical or physical processes that isolate the components of the sample. Typically, the mobile phase is either a liquid or gas, while the stationary phase is either a solid or a liquid layer applied to a solid surface.
Chromatographic techniques are typically named by...
Chromatographic techniques are typically named by...
Qualitative Analysis
Qualitative analysis is the process of identifying elements, ions, or compounds in an unknown sample. It is the first and most fundamental type of analysis based on the hierarchy of analytical goals. This hierarchy is significant as it provides a structured approach to scientific research, with qualitative analysis serving as the initial step, providing essential information before moving on to quantitative or other forms of analysis.
There are two main approaches to qualitative analysis:...
There are two main approaches to qualitative analysis:...
Ultraviolet and Visible (UV–Vis) Spectroscopy: Overview
Ultraviolet–visible (UV–visible or UV–Vis) spectroscopy is an analytical technique that investigates the interaction between matter and UV–Vis light within the electromagnetic spectrum. This method is widely used for its versatility, simplicity, and relatively quick data acquisition, making it valuable for both qualitative and quantitative analysis. When UV–Vis radiation passes through a material, molecules absorb light depending on the energy required for electronic transitions. As a result...
UV–Vis Spectrometers
The absorbance of UV and visible (UV–visible) radiations is measured using a UV–visible spectrophotometer. Deuterium lamps, which emit UV radiation, and tungsten lamps, which produce radiation in the visible region, are used as light sources in UV–visible spectrophotometers. A monochromator or prism is used for diffraction grating, i.e., to split the incoming radiation into different wavelengths. A system of slits is used to focus the desired wavelength on the sample cell. Samples for...
IR and UV–Vis Spectroscopy of Aldehydes and Ketones
Infrared spectroscopy, also known as vibrational spectroscopy, is mainly used to determine the types of bonds and functional groups in molecules. In aldehydes and ketones, the carbonyl (C=O) bond shows an absorption around 1710 cm-1. The C=O bond vibration of an aldehyde occurs at lower frequencies than that of a ketone. In addition to the C=O absorption in an aldehyde, the aldehydic C–H bond also gives two peaks in the 2700–2800 cm-1 range. This absorption, coupled with the C=O stretching, is...
IR and UV–Vis Spectroscopy of Carboxylic Acids
In IR spectroscopy of carboxylic acids, the C=O bond shows a characteristic band between 1710 and 1760 cm⁻¹, and the O–H bond exhibits a broad band between 2500 and 3300 cm⁻¹.
However, the stretching absorptions for the C=O bond vary depending on the structure of carboxylic acids. The C=O bond of the free carboxylic acids shows a higher stretching frequency, 1760 cm−1, while H-bonded carboxylic acids (dimers) exhibit stretching absorptions at a lower frequency, 1710 cm−1. The C=O bond of the...
However, the stretching absorptions for the C=O bond vary depending on the structure of carboxylic acids. The C=O bond of the free carboxylic acids shows a higher stretching frequency, 1760 cm−1, while H-bonded carboxylic acids (dimers) exhibit stretching absorptions at a lower frequency, 1710 cm−1. The C=O bond of the...