Related Experiment Video
Updated: Oct 17, 2026

A Multicenter MRI Protocol for the Evaluation and Quantification of Deep Vein Thrombosis
Published on: June 2, 2015
Predictive value of a rapid semiquantitative D-dimer assay in critically ill patients with suspected venous
M H Kollef1, M Zahid, P R Eisenberg
1Department of Internal Medicine, Washington University School of Medicine, St. Louis, MO, USA.
Objective:
To evaluate the performance of a new, rapid semi-quantitative assay for the detection of circulating D-dimer in whole blood from critically ill patients with suspected venous thromboembolic disease.
Design:
Prospective, blinded, single-center study.
Setting:
Medical intensive care unit (ICU) of Barnes-Jewish Hospital, St. Louis, MO, a university-affiliated urban teaching hospital.
Patients:
Two hundred thirty-nine adult patients with clinical suspicion of venous thromboembolic disease admitted to a medical ICU.
Interventions:
Collection of blood samples within 24 hrs of clinical suspicion of venous thromboembolic disease.
Measurements And Main Results:
The main outcome measures evaluated included the occurrence of venous thromboembolic disease (i.e., lower extremity venous thrombosis, pulmonary embolism, catheter-associated venous thrombosis) and hospital mortality. Fifty-seven patients (23.8%) were classified as having venous thromboembolic disease during their ICU stays (pulmonary embolism, 21 patients; lower extremity thrombosis, 44 patients; line-associated venous thrombosis, 3 patients). The semiquantitative whole-blood assay for circulating D-dimer had a 96.4% sensitivity and a negative predictive value of 92.1% for identifying patients with venous thromboembolic disease. The specificity of this assay was 19.7%, and its positive predictive value was 26.9%. There was a strong correlation between the semiquantitative assay for circulating D-dimer and the quantitative measurement of circulating D-dimer using an enzyme immunoassay (Spearman's correlation coefficient, 0.8643; p<.001). We also identified a strong correlation between both the quantitative and semiquantitative measurements of circulating D-dimer with the sepsis classification proposed by the American College of Chest Physicians/Society of Critical Care Medicine (i.e., systemic inflammatory response syndrome, sepsis, severe sepsis, septic shock) for patients without venous thromboembolic disease (n = 182; quantitative measure: Spearman's correlation coefficient, 0.207; p = .002; semiquantitative measure: Spearman's correlation coefficient, 0.3519; p<.001).
Conclusions:
These preliminary findings suggest that a rapid whole-blood assay for the semiquantitative detection of circulating D-dimer may be a useful diagnostic tool for the exclusion of venous thromboembolic disease among critically ill patients.
Related Concept Videos
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Venous Thrombosis III: Interprofessional Care
Pulmonary Embolism II: Diagnostic Studies and Interprofessional Care
Automated Microbial Diagnostics