The salt output of a nebulizer--a comparison between two nebulizer types
Related Experiment Video
Updated: Oct 17, 2026

Dry Powder and Nebulized Aerosol Inhalation of Pharmaceuticals Delivered to Mice Using a Nose-only Exposure System
Published on: April 6, 2017
L Eklund1, B M Sundblad, P Malmberg
1Program for Respiratory Health and Climate, National Institute for Working Life, Stockholm, Sweden.
Abstract:
The output of a nebulizer is generally defined as its weight loss during 1 min of nebulization. This mass output includes the weight loss due to evaporation of the solution required to moisten the dry air that is fed through the nebulizer. In order to compare results obtained from studies using different nebulizers we introduce the salt output as the amount of the solution that actually leaves the liquid phase as droplets and not by evaporation. The performance characteristics of a standard jet nebulizer (MA2) and a Sidestream jet neublizer were compared. Mass output was determined at different methacholine concentrations. Salt output was assessed by analysing the remaining salt in the nebulizers after 1 min of nebulization. Overall system performance in terms of forced expiratory volume in 1 sec (FEV1) reduction after 1 min of exposure to individually selected concentrations of methacholine were studied in 15 healthy, non-smoking subjects. Both nebulizer types showed a moderate linear increase of mass output with methacholine concentration. The efficiency coefficient, the quotient between salt output and mass output, was found to be 0.93 and 0.75 for the MA2 and Sidestream nebulizer respectively. These findings were explained by differences in airflow through, and temperature inside, the nebulizers. The salt output of the nebulizers proved to be better correlated to the FEV1-reduction following methacholine inhalation than did the mass output. The relative amount of the salt output that adhered to the acrylic walls of the Sidestream nebulizer drying tower was found to be 9%. We conclude that it is more appropriate to use salt output than mass output as a nebulizer performance descriptor. The study also shows the importance of determining nebulizer system performance under conditions as similar to true provocations as possible.
More Related Videos
Related Concept Videos
Inhaled Medications
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Asthma-IV: Diagnostic and Management
Clinical Assessment for Asthma:
This is the first step in diagnosing and managing asthma. It includes:
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils, connected...
Suctioning the Nasopharyngeal Airway
Equipment Required