Related Experiment Video
Updated: Aug 15, 2026

Using a Chemical Biopsy for Graft Quality Assessment
Published on: June 17, 2020
Optimized stationary phases for the high-performance liquid chromatography-electrospray ionization mass spectrometric
S R Needham1, P R Brown, K Duff
1Pfizer, Inc., Candidate Synthesis Enhancement and Evaluation Group, Groton, CT 06340, USA. shane_r_needham@groton.pfizer.com
Abstract:
Stationary phases were investigated for HPLC coupled with electrospray ionization mass spectrometry (ESI-MS) for the analysis of basic drugs. Tricyclic antidepressants (TCAs) and beta-blockers were used as model solutes. The functional groups, pentafluorophenyl (PFP), OH, CN or CH3 were attached to the silica via a propyl chain. The effects of these stationary phases as well as C8 and C18 phases on retention and peak shape of the basic drugs were studied. The CN and PFP phases adequately retained (tR of 2 to 6 min) the basic drugs when the mobile phase was composed of 90% acetonitrile, whereas with the C4, C8 and C18 phases, less than 40% acetonitrile had to be used to provide adequate retention of the basic drugs. Because acetonitrile provides better desolvation in ESI than an aqueous solvent, it produces an increased MS signal. As an example of the HPLC-ESI-MS analysis of the beta-blocker, pindolol, on a CN phase, the use of 90% acetonitrile in the mobile phase increased the ESI-MS signal by 790% when compared to a C18 phase which could use only 5% acetonitrile in the mobile phase for retention of the solute. In addition, the CN and PFP phases provided better peak shape than the OH phase and the hydrophobic phases (C4, C8 and C18) and ion-pairing or ion-suppressing agents were not required. The retention behavior of the TCAs and beta-blockers on each of the phases is described.
More Related Videos
09:09Preparation of Human Tissues Embedded in Optimal Cutting Temperature Compound for Mass Spectrometry Analysis
Published on: April 27, 2021
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
Related Concept Videos
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Instrumentation
Ion-Exchange Chromatography