Differences between lactate concentration of samples from ear lobe and the finger tip
J Feliu1, J L Ventura, R Segura
1Department of Physiological Sciences II. University of Barcelona, Spain.
Journal of Physiology and Biochemistry
|March 24, 2000
Summary
Blood lactate measurements from finger tips are not equivalent to ear lobe samples. Finger tip samples consistently yield higher lactate concentrations, impacting athletic training program assessments.
Area of Science:
- Sports Medicine
- Exercise Physiology
- Biochemistry
Background:
- Blood lactate concentrations are commonly measured from capillary samples.
- Ear lobe and finger tip sampling sites are often used interchangeably for blood lactate analysis.
- This interchangeable use assumes equivalence, which may impact athletic training program design.
Purpose of the Study:
- To investigate the validity of using ear lobe and finger tip capillary blood samples interchangeably for lactate measurements.
- To determine if significant differences exist in blood lactate concentrations between these two sampling sites.
- To assess the practical implications for athletic training program planning and evaluation.
Main Methods:
- Twenty-six elite male athletes (rowers, cyclists, runners) underwent graded exercise tests to exhaustion.
- Simultaneous capillary blood samples were collected from the ear lobe and finger tip at rest, submaximal, and post-exhaustion.
- Lactate concentrations were analyzed from paired samples at three distinct physiological states.
Main Results:
- Significant differences (p < 0.001) were observed in blood lactate concentrations between ear lobe and finger tip samples.
- Finger tip samples consistently demonstrated higher lactate values compared to ear lobe samples.
- Method errors for lactate measurements varied: 27% (rest), 16% (submaximal), and 3% (maximal exercise).
Conclusions:
- The assumption of equivalence between ear lobe and finger tip blood lactate measurements is invalid.
- Finger tip sampling provides higher lactate concentrations than ear lobe sampling.
- This discrepancy necessitates careful consideration when interpreting blood lactate data for athletic training.