Inhibition of platelet thrombosis using an activated protein C-loaded stent: in vitro and in vivo results
Related Experiment Video
Updated: Jul 17, 2026

A Murine Model of Stent Implantation in the Carotid Artery for the Study of Restenosis
Published on: May 14, 2013
R S Foo1, A H Gershlick, K Hogrefe
1Department of Medicine and Therapeutics, Leicester University, UK. rf226@medschl.cam.ac.uk
In high-risk and complicated coronary intervention, the risk of acute closure is unpredictable. Thrombus and platelet deposition at the intervention site may also have further effects on subsequent restenosis. In vivo infusion of activated protein C has previously been shown to achieve potent anticoagulation without any haemostatic side effects. We now evaluated the in vitro and in vivo efficacy of polymer-coated coronary stents loaded with purified rabbit Activated Protein C (APC). By measuring 125I-fibrinogen/fibrin deposition APC-loaded stent-wires were antithrombotic compared to albumin-loaded, inhibited-APC-loaded, plain polymer-coated and stainless steel stent-wires. In a balloon injury rabbit iliac artery model, APC-loaded stents did not occlude (0/14) compared to plain stents (9/15) and BSA-loaded stents (2/4). Relative 111In-labelled platelet deposition showed a similarly significant degree of inhibition. In conclusion, APC-loading could render stents significantly less thrombotic. Whether an effective antithrombogenic stent like this effectively reduces restenosis rates warrants further evaluation.
In high-risk and complicated coronary intervention, the risk of acute closure is unpredictable. Thrombus and platelet deposition at the intervention site may also have further effects on subsequent restenosis. In vivo infusion of activated protein C has previously been shown to achieve potent anticoagulation without any haemostatic side effects. We now evaluated the in vitro and in vivo efficacy of polymer-coated coronary stents loaded with purified rabbit Activated Protein C (APC). By measuring 125I-fibrinogen/fibrin deposition APC-loaded stent-wires were antithrombotic compared to albumin-loaded, inhibited-APC-loaded, plain polymer-coated and stainless steel stent-wires. In a balloon injury rabbit iliac artery model, APC-loaded stents did not occlude (0/14) compared to plain stents (9/15) and BSA-loaded stents (2/4). Relative 111In-labelled platelet deposition showed a similarly significant degree of inhibition. In conclusion, APC-loading could render stents significantly less thrombotic. Whether an effective antithrombogenic stent like this effectively reduces restenosis rates warrants further evaluation.
Related Concept Videos
Anticoagulant Drugs: Low-Molecular-Weight Heparins
Antiplatelet Drugs: Prostaglandin Synthesis, P2Y12 and Glycoprotein IIb/IIIa Inhibitors
Prostaglandin synthesis inhibitors, exemplified by the widely known aspirin, wield their power by irreversibly acetylating...
Formation of the Platelet Plug
As the injured blood vessel contracts, endothelial cells undergo contraction, revealing collagen fibers in the basement membrane and underlying connective tissue. Furthermore, the plasma membrane of endothelial cells becomes adhesive, preparing the site for platelet adhesion. Platelets...
Clot Retraction and Fibrinolysis
Peripheral Artery Disease III: Interprofessional Care
Venous Thrombosis III: Interprofessional Care